Contact SCGE




SCGE Consortium Home   |  About SCGE Toolkit   |  Contact Us   |  Citing the Toolkit   |  License  
ExperimentAAV tropism in kidney organoids cultured under flow
Experiment ConditionControl, High Flow on Chip
Assay Description: Calculated total transduction efficiency by counting fluorescent cells (GFP) compared to DAPI stained cells.
Tissue Measured:
Measurement Type:Delivery Efficiency
Record ID15000003415

Editor
Delivery System
Delivery System Subtype
Guide
Vector

Model SpeciesHuman
Model NameHuman kidney organoid (stem cell-derived)

Application Methodcontrol
Application Site
Dosagecontrol
Injection Frequency
Injection Rate
Injection Volume
Days post injection7 days
Editor FormatAAV vector encoded
Antidote Id
Antidote Description

Antibody RRIDRRID:AB_300798
Antibody Other IDab13970 (Abcam)
Antibody DescriptionChicken anti-GFP polyclonal antibody

Antibody RRIDRRID:AB_2336558
Antibody Other IDB-1325-2 (Vector Labs)
Antibody DescriptionLotus tetragonolobus lectin (LTL)

Antibody RRIDRRID:AB_354920
Antibody Other IDAF1658 (R&D Systems)
Antibody DescriptionGoat anti-podocalyxin polyclonal antibody

Measured Values
Samples Size: 2
 
Replicate Result (Delivery Efficiency)
Measurement Units: %GFP+ Area
Mean 0.01 
1 0.012 
2 0.015 
Measurement Units: %GFP+ LTL+ / LTL+ cells
Mean
1
Measurement Units: %GFP+ PODXL+ / PODXL+ cells
Mean 0.05 
1 0.051374